7.2

Door state diagnostics

Source section

Door State shows Access Decision, Lock Type, Door Control, output state and current input conditions.

7.5

Reader bus health

Source section

Reader Bus Health shows CRC errors, offline transitions and bus voltage.

9.4

Support bundle

Source section

Export a support bundle from Diagnostics > Support Bundle before escalation when the fault is intermittent.